Development of innovative landfill gas management technologies

In: Fjelsted , L 2019 , Development of innovative landfill gas management technologies . Technical University of Denmark , Kgs. Lyngby, Denmark .

Abstract

Verden over er de globale klimaforandringer på den politiske dagsorden, og der er et stigende behov for strategier, som kan mindske udledningen af drivhusgasser. En kilde til udledningen af drivhusgasser er deponeret affald, hvor nedbrydningen af organisk kulstof danner metan. Emissionen af deponigas er meget dynamisk med en stor rumlig og tidslig variation. Der er derfor behov for udvikling af innovative teknologier til både måling og håndtering af deponigas, som kan hjælpe i den nødvendige konceptuelle forståelse af, hvad der styrer gastransporten og udledningsprocesserne. En metanbalance kan opstilles på baggrund af den dannede metans forskellige migrations veje, som inkluderer opsamling med henblik på energiudnyttelse eller afbrænding, horisontalt udslip til naboejendomme, metanoxidation i dæklaget samt emission til atmosfæren. En god konceptuel ramme for udarbejdelsen af en håndteringsstrategi for et deponi er en metan massebalance. Størstedelen af nærværende Ph.d. projekt blev udført i forbindelse med et nedlukket dansk deponi (Hedeland deponi, Roskilde). Mange års intensive undersøgelser har været gennemført på Hedeland deponi, for bedre at forstå under hvilke forhold den dannede deponigas spredes og emitteres til atmosfæren. En håndteringsstrategi, der tager højde for både sikkerheden for naboerne og de negative effekter på klimaet, er nødvendig. En metan massebalance for deponiet kan give et overblik og vise betydningen af de enkelte migrations veje i forhold til hinanden. Som en del af dette Ph.d. projekt er der opstillet en metan massebalance for Hedeland deponi baseret på de store mængder data, der er indsamlet i forbindelse med de mange års undersøgelser, og som dækker årene 2013-2015. Metandannelsen blev modelleret ved brug af en multifase-model baseret på førsteordens nedbrydningshastigheder (Afvalzorg) og den gennemsnitlige metandannelse blev fundet til 67 ±8.6 kg h-1. Metanindvindingen, emissionen og den horisontale migration viste sig at udgøre 38% af den modellerede dannede metan, og de bidrog med en lige stor andel hver (hhv. 9 ±2,9, 8 ±4,1 and 9 ±2,4 kg h-1). Metanoxidation i dæklaget blev identificeret som den spredningsvej, der kunne lukke metanbalancen, og den udgjorde 62% af den dannede metan. Der var adskillige indikationer, som støttede en høj oxidationsrate i dæklaget på Hedeland deponi herunder en lav total emissionsrate bestemt ved brug af sporgasmetoden og få emissions-hotspots med forhøjede koncentrationer af metan på overfladen (fundet ved en overflade screening med en flammeioniserings detektor). Identifikation af emissions-hotspots med lossepladsgas er grundlaget for etableringen af emissionsbegrænsende teknologier så som biocovers. En drone udstyret med at termokamera blev testet på to danske deponier (Hedeland deponi og Audebo deponi) som et muligt screeningsværktøj, der vil kunne imødegå den store rumlige og tidslige variation i lossepladsgas emissionen. Sammenhængen mellem udledningen af lossepladsgas (metan og kuldioxid), overfladetemperaturen målt med termokameraet og jordtemperaturen i 5 og 10 cm dybde blev undersøgt i et testområde på hver er de to deponier. På Hedeland deponi blev der ikke fundet nogen sammenhæng mellem emission af deponigas og overfladetemperaturene. Desuden var de fundne overfladefluxe meget begrænsede, hvor gennemsnitsfluxen for de fire målekampagner var begrænset til 1,3 ±16 g CH4 m-2 d-1. En gennemsnitlig metanflux på 371 ±1337 g CH4 m-2 d-1 blev fundet for Audebo deponi for de fem gennemførte målekampagner. Derudover blev der fundet højere temperaturer både på overfladen og i 5 og 10 cm dybde i de samme områder, hvor de højeste overfladefluxe af deponigas var målt, hvilket indikerer, at termokameraet vil kunne være i stand til at identificere emissioner af deponigas under de rette forhold. En minimumsflux på 150 g CH4 m-2 d-1 fra et område på mindst 1 m2 blev fundet som den nedre grænse for hvornår et termokamera er i stand til at identificere et emissions-hotspot med deponigas på et typisk dansk deponi. En fortynding af deponigas med luft vil ofte resulterer i et metanindhold i den fortyndede deponigas som er for lavt til at gassen kan udnyttes. Dog vil der ofte stadig være behov for at minimere de negative effekter på miljøet og for menneskers sikkerhed. Kilderne til fortyndet deponigas kan være afværgesystemer imod den horisontale spredning af deponigas, emissioner fra perkolat- og overvågningsbrønde eller ved at luft trænger ned i dæklaget på deponiet. En kosteffektiv begrænsningsteknologi for fortyndet deponigas kan være mikrobiel oxidation i et biofilter med aktiv tilførsel af gas. Denne teknologi blev testet i et kompostbaseret åbent pilotskala filter på Hedeland deponi konstrueret i en 30 m3 container. Filteret blev tilført deponigas fortyndet med luft til en metankoncentration på mellem 5 og 10 vol.%. Filteret blev testet i fem flowkampagner med den samme metankoncentration i indløbet i alle fem kampagner, men med en stigene metantilførsel, der resulterede i en tilførsel på mellem 106 og 794 g CH4 m-2 d-1. Den højeste fundene metanoxidationsrate var 460 g CH4 m-2 d-1 med en oxidationseffektivitet på 58%. Den højeste samlede oxidationseffektivitet, der blev fundet var 87%, og en højere effektivitet blev aldrig opnået på grund af væsentlig præferentiel transport langs siderne mellem komposten og containervæggen til trods for de installerede blokader designet til at begrænse det selektive flow. Dog viste gasprofiler i komposten en metanoxidation på næsten 100%. Test med en sporgas understøttede disse resultater og viste en metanoxidation på 86% 10 cm under filteroverfladen ved flowkampagne 5, hvor der gennemsnitligt blev tilført 701 ±47 g CH4 m-2 d-1 til filteret. På Hedeland deponi er der installeret tre afværgesystemer for at afskære den horisontale spredning af lossepladsgas til beboelsesejendommene på nabogrundene. I 2017 blev der målt et gennemsnitlig metanindhold i den oppumpede gas fra alle tre anlæg på 0,53 ±0,55 vol.% og med et indhold af ilt på over 10 vol.% i de fleste tilfælde. Håndteringen af den oppumpede afværgegas i det testede pilotskala biofilter vil resultere i en metan tilførsel på 717 g CH4 m-2 d-1. På grund af den høje pumperate på 80 m3 h-1 vil gassens opholdstid i filteret dog kun være på 3 minutter, hvilket forventes at være mindre end den nødvendige opholdstid. Ti filtre med det samme volumen som det testede filter er nødvendigt for at øge opholdstiden til 30 min. Et foreslået alternativ kunne være et 111 m2 biofilter indbygget i deponiets slutafdækning, som vil resultere i den samme mængde metan tilført pr. arealenhed som til de ti containere. Et biofilter indbygget i dæklaget kan også være en løsning på problemerne med det selektive flow ved containerløsningen. ; Climate change is on the political agenda worldwide, and abatement strategies for greenhouse gas emissions are a necessity. One source of greenhouse gas emissions is landfills, as the degradation of organic carbon in landfilled waste generates methane. Landfill gas emission patterns show high spatial and temporal variability, but the development of innovative technologies for both monitoring and mitigation will help in the much-needed conceptual understanding of governing gas transport and emission processes. A methane mass balance can be established based on the individual migration pathways for the generated methane, including methane recovery for energy utilisation or flaring, lateral migration to neighbouring plots, methane oxidation by microorganisms in the cover and emissions seeping into the atmosphere. A methane mass balance forms a good conceptual framework for setting up a mitigation strategy for a landfill. The main part of this PhD project was conducted in relation to a closed Danish landfill (Hedeland landfill, Roskilde, Denmark). Many years of intensive investigations have been conducted at Hedeland landfill to understand better the migration and emission patterns of methane generated at the site. A mitigation strategy has to be established, which takes into consideration both the safety of local residents and the negative impact on global warming from landfill gas migration and emission. A methane mass balance for the landfill could provide a valuable overview and show the individual importance of each migration pathway. As part of this PhD project, a methane mass balance was established for Hedeland landfill based on data from many years of investigation, covering the years 2013-2015. Methane generation was modelled based on a multi-phase, first-order degradation kinetics (Afvalzorg) model, with average methane generation determined at 67±8.6 kg h-1. Methane recovery, emission and lateral migration were found to cover 38% of the modelled methane generation, each accounting for an equal share (9 ±2.9, 8 ±4.1 and 9 ±2.4 kg h-1, respectively). Methane oxidation in the cover was identified as the migration pathway capable of closing the mass balance and accounting for the remaining 62% of the generated methane. Several indications supported a high oxidation rate in the landfill cover at Hedeland, including a low total emission rate, which was determined using the tracer gas dispersion method and a few emission hotspots with elevated methane concentrations at the surface (identified by screening the whole landfill surface, using a flame ionisation detector). Identification of landfill gas emission hotspots is the basis for establishing emission abatement technologies such as biocovers. To overcome the high spatial and temporal variability of landfill gas emissions, a screening tool based on an unmanned aerial system mounted with a thermal infrared (TIR) camera was tested at two Danish landfills (Hedeland and Audebo landfills). The correlation between landfill gas emissions (methane and carbon dioxide), surface temperatures obtained with the TIR camera and soil temperatures at 5- and 10-cm depths was investigated in an established test area at each of the two sites. At Hedeland landfill, no correlation was found between gas emissions and surface temperatures. In addition, identified methane surface fluxes were very limited, with an average for the four measuring campaigns of only 1.3 ±16 g CH4 m-2 d-1. An average methane flux of 371 ±1337 g CH4 m-2 d-1 was found at Audebo landfill for five measuring campaigns. Furthermore, elevated temperatures at both the surface and at 5- and 10-cm depths were found in the same area as where the highest landfill gas surface fluxes were measured, thus indicating that in the right conditions the TIR camera could be used for delineating landfill gas emissions. A minimum flux of 150 g CH4 m-2 d-1 from an area of at least 1 m2 was established as the limit for the TIR camera being able to delineate a landfill gas emission hotspot at a typical Danish landfill. When landfill gas is mixed with air it dilutes, often with a methane content too low for utilisation. However, mitigation is still needed to minimise the negative impacts on the environment, and to ensure human health and safety. Sources to dilute landfill gas could be remediation systems for lateral migration, emissions from leachate and monitoring wells or from air penetrating the cover of the landfill. A cost-efficient mitigation technology for dilute landfill gas could be microbial oxidation in an actively loaded biofilter. This technology was tested in an open-bed pilot-scale compost filter at Hedeland landfill, constructed in a 30 m3 container. The filter was loaded with landfill gas diluted with ambient air to a methane concentration of between 5 and 10 vol.%. The filter was tested in five flow campaigns with the same methane inlet concentration and an increasing methane load between 106 and 794 g CH4 m-2 d-1. The highest observed methane oxidation rate was 460 g CH4 m-2 d-1 with an oxidation efficiency of 58%. Overall, oxidation efficiencies of more than 87% were never achieved, due to substantial preferential flows at the transition point between the compost and container wall despite an attempt to design the container with blockers against preferential flows. However, pore gas profiles showed methane oxidation of 100% in the compost material. These results were supported by tracer gas tests showing an average methane oxidation of almost 86% at 10 cm below the surface of the filter in flow campaign 5, where the load had an average of 701 ±47 g CH4 m-2 d-1. At Hedeland landfill, three remediation systems have been installed to cut off laterally migrating landfill gas from reaching residential houses on neighbouring plots. In 2017, an average methane content of 0.53 ±0.55 vol.% in off-gas from these remediation systems was observed, accompanied by an oxygen content in most cases above 10 vol.%. Treatment of the remediation off-gas in the constructed pilot-scale biofilter would result in a methane load of 717 g CH4 m-2 d-1. Nevertheless, the gas retention time would only be 3 min, due to the high pump flow rate of 80 m3 h-1, which is thought to be below a critical gas retention time. To increase the retention time to 30 min, ten containers similar to the tested filter would be needed. A suggested alternative could be a 111 m2 biofilter embedded in the landfill cover, which would result in the same load as the ten containers. An embedded biofilter is also expected to be able to overcome the challenges of preferential flows experienced in the tested container solution.

Sprachen

Englisch

Verlag

Technical University of Denmark

Problem melden

Wenn Sie Probleme mit dem Zugriff auf einen gefundenen Titel haben, können Sie sich über dieses Formular gern an uns wenden. Schreiben Sie uns hierüber auch gern, wenn Ihnen Fehler in der Titelanzeige aufgefallen sind.