Open Access BASE2020

Availability and use of continuous positive airway pressure (CPAP) for neonatal care in public health facilities in India: a cross-sectional cluster survey

Abstract

OBJECTIVES: To determine the availability of continuous positive airway pressure (CPAP) and to provide an overview of its use in neonatal units in government hospitals across India. SETTING: Cross-sectional cluster survey of a nationally representative sample of government hospitals from across India. PRIMARY OUTCOMES: Availability of CPAP in neonatal units. SECONDARY OUTCOMES: Proportion of hospitals where infrastructure and processes to provide CPAP are available. Case fatality rates and complication rates of neonates treated with CPAP. RESULTS: Among 661 of 694 government hospitals with neonatal units that provided information on availability of CPAP for neonatal care, 68.3% of medical college hospitals (MCH) and 36.6% of district hospitals (DH) used CPAP in neonates. Assessment of a representative sample of 142 hospitals (79 MCH and 63 DH) showed that air-oxygen blenders were available in 50.7% (95% CI 41.4% to 60.9%) and staff trained in the use of CPAP were present in 56.0% (45.8% to 65.8%) of hospitals. The nurse to patient ratio was 7.3 (6.4 to 8.5) in MCH and 6.6 (5.5 to 8.3) in DH. Clinical guidelines were available in 31.0% of hospitals (22.2% to 41.4%). Upper oxygen saturation limits of above 94% were used in 72% (59.8% to 81.6%) of MCH and 59.3% (44.6% to 72.5%) of DH. Respiratory circuits were reused in 53.8% (42.3% to 63.9%) of hospitals. Case fatality rate for neonates treated with CPAP was 21.4% (16.6% to 26.2%); complication rates were 0.7% (0.2% to 1.2%) for pneumothorax, 7.4% (0.9% to 13.9%) for retinopathy and 1.4% (0.7% to 2.1%) for bronchopulmonary dysplasia. CONCLUSIONS: CPAP is used in neonatal units across government hospitals in India. Neonates may be overexposed to oxygen as the means to detect and treat consequences of oxygen toxicity are insufficient. Neonates may also be exposed to nosocomial infections by reuse of disposables. Case fatality rates for neonates receiving CPAP are high. Complications might be under-reported. Support to infrastructure, training, guidelines ...

Sprachen

Englisch

Verlag

BMJ Publishing Group

DOI

10.1136/bmjopen-2019-031128

Problem melden

Wenn Sie Probleme mit dem Zugriff auf einen gefundenen Titel haben, können Sie sich über dieses Formular gern an uns wenden. Schreiben Sie uns hierüber auch gern, wenn Ihnen Fehler in der Titelanzeige aufgefallen sind.