Laboratory Investigation into the Performance of an In‐Sewer Vortex Flow Regulator

In: Water and environment journal, Band 7, Heft 2, S. 182-189

Verfügbarkeit an Ihrem Standort wird überprüft

Abstract

AbstractAspects of the hydraulic performance of an in‐sewer vortex regulator have been studied. These devices are increasingly used in stormwater management schemes, but their characteristics under a variety of prototypical situations have not been widely disseminated. The study used a full‐size laboratory mockup of a section of sewer and associated manhole with facilities for measuring discharges of up to 60 1/s. The performance of a typical vortex flow regulator was investigated under both steady and unsteady flow conditions. The steady head‐discharge relationship revealed the expected 'kick back'region (during rising head); however, this was less pronounced during falling head. Under unsteady conditions, vortex initiation was affected and a hysteresis effect was noted. The influence of downstream surcharge was significant at lower upstream heads. Theoretical comparison showed that to obtain equivalent performance, an orifice of 62% of the diameter of the vortex regulator would be required, and 25% savings in storage could be made.