Occurrence of tropane alkaloids in food
In: EFSA supporting publications, Band 13, Heft 12
ISSN: 2397-8325
7 Ergebnisse
Sortierung:
In: EFSA supporting publications, Band 13, Heft 12
ISSN: 2397-8325
In: Environmental science and pollution research: ESPR, Band 20, Heft 11, S. 7930-7939
ISSN: 1614-7499
In: STOTEN-D-22-08754
SSRN
The Human Biomonitoring for Europe initiative (HBM4EU) aims to study the exposure of citizens to chemicals and potentially associated health effects. One objective of this project has been to build a network of laboratories able to answer to the requirements of European human biomonitoring studies. Within the HBM4EU quality assurance and quality control scheme (QA/QC), a number of interlaboratory comparison investigations (ICIs) and external quality assurance schemes (EQUASs) were organized to ensure data consistency, comparability and reliability. Bisphenols are among the prioritized substance groups in HBM4EU, including bisphenol A (BPA), bisphenol S (BPS) and bisphenol F (BPF) in human urine. In four rounds of ICI/EQUAS, two target concentration levels were considered, related to around P25 and P95 of the typical exposure distribution observed in the European general population. Special attention was paid to the conjugated phase II metabolites known to be most dominant in samples of environmentally exposed individuals, through the analysis of both native samples and samples fortified with glucuronide forms. For the low level, the average percentage of satisfactory results across the four rounds was 83% for BPA, 71% for BPS and 62% for BPF. For the high level, the percentages of satisfactory results increased to 93% for BPA, 89% for BPS and 86% for BPF. 24 out of 32 participating laboratories (75%) were approved for the analyses of BPA in the HBM4EU project according to the defined criterion of Z-scores for both low and high concentration levels in at least two ICI/EQUAS rounds. For BPS and BPF, the number of qualified laboratories was 18 out of 27 (67%) and 13 out of 28 (46%), respectively. These results demonstrate a strong analytical capability for BPA and BPS in Europe, while improvements may be needed for BPF. ; We gratefully acknowledge funding by the European Union's Horizon 2020 research and innovation programme under the grant agreement No. 733032 HBM4EU. The authors would like to thank the HBM4EU ...
BASE
Standard methods for chemical food safety testing in official laboratories rely largely on liquid or gas chromatography coupled with mass spectrometry. Although these methods are considered the gold standard for quantitative confirmatory analysis, they require sampling, transferring the samples to a central laboratory to be tested by highly trained personnel, and the use of expensive equipment. Therefore, there is an increasing demand for portable and handheld devices to provide rapid, efficient, and on-site screening of food contaminants. Recent technological advancements in the field include smartphone-based, microfluidic chip-based, and paper-based devices integrated with electrochemical and optical biosensing platforms. Furthermore, the potential application of portable mass spectrometers in food testing might bring the confirmatory analysis from the laboratory to the field in the future. Although such systems open new promising possibilities for portable food testing, few of these devices are commercially available. To understand why barriers remain, portable food analyzers reported in the literature over the last ten years were reviewed. To this end, the analytical performance of these devices and the extent they match the World Health Organization benchmark for diagnostic tests, i.e., the Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment-free, and Deliverable to end-users (ASSURED) criteria, was evaluated critically. A five-star scoring system was used to assess their potential to be implemented as food safety testing systems. The main findings highlight the need for concentrated efforts towards combining the best features of different technologies, to bridge technological gaps and meet commercialization requirements. ; This project has received funding from the European Union's Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreement No 720325, FoodSmartphone. ; Peer reviewed
BASE
A fundamental objective of the human biomonitoring for Europe initiative (HBM4EU) is to progress toward comparable and robust exposure data for a wide variety of prioritized chemicals in human samples. A programme for Quality Assurance/Quality Control (QA/QC) was designed in HBM4EU with the purpose of creating a network of European laboratories providing comparable analytical data of high quality. Two approaches were chosen for two sets of prioritized chemicals with different timelines: (i) Scheme 1, where interested candidate laboratories participated in multiple rounds of proficiency tests (ii) Scheme 2, where selected expert laboratories participated in three rounds of interlaboratory comparison investigations. In both cases, the results were used to identify laboratories capable of generating consistent and comparable results for sample analysis in the frame of HBM4EU. In total, 84 laboratories from 26 countries were invited to participate in Scheme 1 that covered up to 73 biomarkers from Hexamoll® DINCH, phthalates, bisphenols, per- and polyfluoroalkyl substances, halogenated flame retardants (HFRs), organophosporous flame retardants (OPFRs), polycyclic aromatic hydrocarbons (PAH), cadmium, chromium and aromatic amines. 74 of the participants were successful for at least one biomarker in Scheme 1. Scheme 2 involved 22 biomarkers and successful results were obtained by 2 expert laboratories for arsenic, 5 for acrylamide, 4 for mycotoxins, 2 for pesticides and 2 for UV-filters in skin care products. The QA/QC programme allowed the identification of major difficulties and needs in HBM analysis as well of gaining insight in the analytical capacities of European laboratories. Furthermore, it is the first step towards the establishment of a sustainable European network of HBM laboratories. ; This study was part of the HBM4EU project receiving funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 733032. The authors acknowledge all the participating and expert laboratories (Centre de Toxicologie du Québec/Institut National de Santé Publique du Québec; IDEA Consultants, Inc.; Otsuka Pharmaceutical Co., Ltd.; Otsuka Pharmaceutical Co., Ltd.; Arizona Department of Health Services Laboratory; Centers for Disease Control and Prevention (CDC); New York State Department of Health Wadsworth Center; Wisconsin State Laboratory of Hygiene), that made the HBM4EU QA/QC programme possible, as well as the Management and Advisory Boards of HBM4EU. ; Sí
BASE
The European Human Biomonitoring Initiative (HBM4EU) is coordinating and advancing human biomonitoring (HBM). For this purpose, a network of laboratories delivering reliable analytical data on human exposure is fundamental. The analytical comparability and accuracy of laboratories analysing flame retardants (FRs) in serum and urine were investigated by a quality assurance/quality control (QA/QC) scheme comprising interlaboratory comparison investigations (ICIs) and external quality assurance schemes (EQUASs). This paper presents the evaluation process and discusses the results of four ICI/EQUAS rounds performed from 2018 to 2020 for the determination of ten halogenated flame retardants (HFRs) represented by three congeners of polybrominated diphenyl ethers (BDE-47, BDE-153 and BDE-209), two isomers of hexabromocyclododecane (α-HBCD and γ-HBCD), two dechloranes (anti-DP and syn-DP), tetrabromobisphenol A (TBBPA), decabromodiphenylethane (DBDPE), and 2,4,6-tribromophenol (2,4,6-TBP) in serum, and four metabolites of organophosphorus flame retardants (OPFRs) in urine, at two concentration levels. The number of satisfactory results reported by laboratories increased during the four rounds. In the case of HFRs, the scope of the participating laboratories varied substantially (from two to ten) and in most cases did not cover the entire target spectrum of chemicals. The highest participation rate was reached for BDE-47 and BDE-153. The majority of participants achieved more than 70% satisfactory results for these two compounds over all rounds. For other HFRs, the percentage of successful laboratories varied from 44 to 100%. The evaluation of TBBPA, DBDPE, and 2,4,6-TBP was not possible because the number of participating laboratories was too small. Only seven laboratories participated in the ICI/EQUAS scheme for OPFR metabolites and five of them were successful for at least two biomarkers. Nevertheless, the evaluation of laboratory performance using Z-scores in the first three rounds required an alternative approach compared to HFRs because of the small number of participants and the high variability of experts' results. The obtained results within the ICI/EQUAS programme showed a significant core network of comparable European laboratories for HBM of BDE-47, BDE-153, BDE-209, α-HBCD, γ-HBCD, anti-DP, and syn-DP. On the other hand, the data revealed a critically low analytical capacity in Europe for HBM of TBBPA, DBDPE, and 2,4,6-TBP as well as for the OPFR biomarkers. ; We gratefully acknowledge funding by the European Union's Horizon 2020 research and innovation programme under the grant agreement No. 733032. ; Sí
BASE