STRANGE LOGIC
In: The current digest of the post-Soviet press, Band 45, Heft 6, S. 17-18
ISSN: 1067-7542
7 Ergebnisse
Sortierung:
In: The current digest of the post-Soviet press, Band 45, Heft 6, S. 17-18
ISSN: 1067-7542
In: The current digest of the post-Soviet press, Band 45, Heft 10, S. 21-22
ISSN: 1067-7542
In: The current digest of the Soviet press: publ. each week by The Joint Committee on Slavic Studies, Band 44, S. 24-25
ISSN: 0011-3425
In: Proceedings of the National Academy of Sciences of Belarus, Physical-Technical Series, Band 66, Heft 3, S. 356-364
ISSN: 2524-244X
In this work, the following tasks were solved: to perform a comparative analysis of data processing methods when calculating recovery factors; to evaluate the influence of time-of-flight technology and PSF function on the recovery factor and the forecast of recovery factor deviation for potential pathological foci with a diameter of 6–8 mm; to evaluate the influence of parameters of iterative reconstruction algorithms, Gaussian filter and axial filters on the recovery factor. The calculation of the recovery factors was carried out on the basis of quantitative characteristics obtained in the analysis of reconstructions of images of the IEC phantom with six spheres installed inside and filled with a radiopharmaceutical. Eight series of experiments with background / sphere activity ratios 1/3, 1/4, 1/6, 1/8, 1/12, 1/14, 1/16, 1/20 were carried out with the same concentration of activity in the spheres during each separate experiment. The forecast of the effect of the partial volume effect on lesions with a diameter of 6 to 8 mm was carried out, taking into account the used reconstruction algorithms. It is advisable to use the results obtained to harmonize diagnostic protocols for scanning with positron emission tomographs using the input parameters of reconstruction algorithms and filters, which will minimize the error in the quantitative assessment of a radiopharmaceutical when analyzing the dynamics of the development of a pathological process, as well as the response of pathology to therapy.
In: Proceedings of the National Academy of Sciences of Belarus, Physical-Technical Series, Band 66, Heft 4, S. 496-504
ISSN: 2524-244X
The description of the original phantom design for assessing the quantitative characteristics of PET images in the study of dynamic objects is given. The phantom movement is controlled by the breath synchronization system, which records the phantom movement amplitude and the duration of the movement cycle. A curve was obtained that simulates human breathing, the parameters of which (amplitude and period) correspond to those obtained in the study of the chest. The values of the ecovery coefficients and contrast are obtained taking into account the sizes of the spheres, as well as the static and dynamic types of movement of phantoms. An assessment of the discrepancy between the recovery coefficients and the contrast values for the spheres installed inside the phantom in the static and dynamic states has been made. With a decrease in the diameter (respectively, and volume) of the sphere, an increase in the difference in values (between the static and dynamic positions of the phantom) of the recovery coefficient is observed. The optimal values of the recovery coefficients obtained using the QClear reconstruction algorithm have been determined. Recommendations for the use of the developed device in the study of dynamic objects are described. It is advisable to use the installation presented in this work to control the quality of the qualitative and quantitative characteristics of diagnostic images obtained both on PET/CT scanners and during studies using SPECT/CT (single-photon emission tomograph combined with a computed tomograph).